{"product_id":"victron-ve-direct-right-angle-cable-5m-ass030531250","title":"Victron VE.Direct Right Angle Cable 5m - ASS030531250","description":"\u003cdiv style=\"font-family:'Inter', -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif; font-size:15px; line-height:1.6; color:#2D3748; text-transform:none; max-width:1100px; margin:0 auto;\"\u003e\n\n  \u003c!-- Hero --\u003e\n  \u003csection style=\"background:linear-gradient(135deg,#031725 0%,#06253D 62%,#02111F 100%); color:#FFFFFF; padding:34px 26px; border-radius:14px; margin-bottom:24px; border:1px solid rgba(46,145,229,0.35); box-shadow:0 14px 34px rgba(6,37,61,0.16);\"\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:24px; align-items:center;\"\u003e\n      \u003cdiv\u003e\n        \u003cp style=\"margin:0 0 10px 0; color:#7DC8FF; font-size:12px; font-weight:700; letter-spacing:0.14em; text-transform:uppercase;\"\u003eLong-reach, low-profile Victron connection\u003c\/p\u003e\n        \u003ch1 style=\"margin:0; color:#FFFFFF; font-size:32px; line-height:1.16; font-weight:700; letter-spacing:-0.02em; text-transform:none;\"\u003e\n          Victron VE.Direct Right Angle Cable 5m (16ft) | Part # ASS030531250\n        \u003c\/h1\u003e\n        \u003cp style=\"margin:12px 0 0 0; color:#D9ECFF; font-size:16px; line-height:1.55; max-width:760px;\"\u003e\n          A genuine Victron Energy 5m VE.Direct cable with one 90-degree connector for clean, long-reach data routing in RV, marine, vehicle, and off-grid installations.\n        \u003c\/p\u003e\n        \u003cp style=\"margin:18px 0 0 0; color:#FFFFFF; max-width:860px;\"\u003e\n          The Victron VE.Direct right angle cable 5m is the exact factory accessory for installers who need both shallow-panel clearance and approximately 16.4 feet of routing reach. Part ASS030531250 combines one low-profile 90-degree VE.Direct connector with one straight connector, helping connect supported SmartSolar or BlueSolar MPPTs, BMV monitors, SmartShunts, Orion XS units, Smart IP43 chargers, and GX monitoring devices without improvised splices or excessive connector strain.\n        \u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003caside style=\"background:rgba(255,255,255,0.07); border:1px solid rgba(46,145,229,0.45); border-radius:12px; padding:22px;\"\u003e\n        \u003cp style=\"margin:0; color:#FFFFFF; font-size:20px; line-height:1.35; font-weight:700;\"\u003eMore reach. Less rear clearance.\u003c\/p\u003e\n        \u003cdiv style=\"height:1px; background:rgba(125,200,255,0.45); margin:18px 0;\"\u003e\u003c\/div\u003e\n        \u003cp style=\"margin:0; color:#D9ECFF; font-size:13px; letter-spacing:0.08em; text-transform:uppercase;\"\u003eOfficial Victron part ASS030531250\u003c\/p\u003e\n      \u003c\/aside\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Quick specs --\u003e\n  \u003csection style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(170px,1fr)); gap:12px; margin-bottom:28px;\"\u003e\n    \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:18px; text-align:center; box-shadow:0 4px 16px rgba(6,37,61,0.05);\"\u003e\n      \u003cdiv style=\"color:#1A202C; font-size:26px; line-height:1; font-weight:700; letter-spacing:-0.02em;\"\u003e5m\u003c\/div\u003e\n      \u003cdiv style=\"color:#2E91E5; font-size:12px; font-weight:700; letter-spacing:0.12em; text-transform:uppercase; margin-top:8px;\"\u003eApprox. 16.4 ft\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:18px; text-align:center; box-shadow:0 4px 16px rgba(6,37,61,0.05);\"\u003e\n      \u003cdiv style=\"color:#1A202C; font-size:26px; line-height:1; font-weight:700; letter-spacing:-0.02em;\"\u003e90°\u003c\/div\u003e\n      \u003cdiv style=\"color:#2E91E5; font-size:12px; font-weight:700; letter-spacing:0.12em; text-transform:uppercase; margin-top:8px;\"\u003eOne right-angle end\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:18px; text-align:center; box-shadow:0 4px 16px rgba(6,37,61,0.05);\"\u003e\n      \u003cdiv style=\"color:#1A202C; font-size:26px; line-height:1; font-weight:700; letter-spacing:-0.02em;\"\u003e4-Pin\u003c\/div\u003e\n      \u003cdiv style=\"color:#2E91E5; font-size:12px; font-weight:700; letter-spacing:0.12em; text-transform:uppercase; margin-top:8px;\"\u003eVE.Direct interface\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:18px; text-align:center; box-shadow:0 4px 16px rgba(6,37,61,0.05);\"\u003e\n      \u003cdiv style=\"color:#1A202C; font-size:26px; line-height:1; font-weight:700; letter-spacing:-0.02em;\"\u003eOEM\u003c\/div\u003e\n      \u003cdiv style=\"color:#2E91E5; font-size:12px; font-weight:700; letter-spacing:0.12em; text-transform:uppercase; margin-top:8px;\"\u003eGenuine Victron\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Trust band --\u003e\n  \u003csection style=\"background:#F7FAFC; border:1px solid #E2E8F0; border-radius:14px; padding:22px; margin-bottom:32px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:0 0 12px 0; line-height:1.35;\"\u003eDual-feature cable for demanding layouts\u003c\/h2\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(165px,1fr)); gap:10px;\"\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#1A202C; font-weight:600;\"\u003eExact part match\u003c\/strong\u003e\u003cspan style=\"color:#4A5568;\"\u003eASS030531250\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#1A202C; font-weight:600;\"\u003eReduced rear depth\u003c\/strong\u003e\u003cspan style=\"color:#4A5568;\"\u003eOne 90-degree connector\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#1A202C; font-weight:600;\"\u003eLong routing reach\u003c\/strong\u003e\u003cspan style=\"color:#4A5568;\"\u003e5m \/ approximately 16.4 ft\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#1A202C; font-weight:600;\"\u003eFactory terminated\u003c\/strong\u003e\u003cspan style=\"color:#4A5568;\"\u003eNo field pinout guesswork\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Clearance focus --\u003e\n  \u003csection style=\"margin-bottom:30px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:24px 0 12px 0; line-height:1.35;\"\u003eSolve Tight Clearances \u0026amp; Prevent Cable Strain\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eA low-profile VE.Direct plug for flush-mounted panels and shallow electrical spaces.\u003c\/p\u003e\n    \u003cp style=\"margin:0 0 14px 0;\"\u003eA standard straight VE.Direct connector projects outward from the equipment and needs room for the plug, cable bend, and service loop. In a shallow RV cabinet, compact marine dashboard, or tightly packed electrical enclosure, that extra depth can force the cable against a wall or create a sharp bend directly at the device port.\u003c\/p\u003e\n    \u003cp style=\"margin:0;\"\u003eVictron's ASS030531xxx right-angle cable family is designed to minimize the depth required behind mounting panels. The 90-degree end on this flush-mount Victron cable turns the cable path alongside the device, helping create a cleaner installation and reducing the need to bend the cable immediately behind the connector.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:14px; margin-top:20px;\"\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:20px;\"\u003e\n        \u003ch3 style=\"margin:0 0 8px 0; color:#1A202C; font-size:17px; line-height:1.4; font-weight:700;\"\u003e90-Degree Low-Profile Connector\u003c\/h3\u003e\n        \u003cp style=\"margin:0;\"\u003eOne end uses Victron's right-angle four-pin VE.Direct plug. Position it at the compatible device with the tightest rear clearance, after confirming that the elbow direction does not block neighboring ports, ventilation paths, or enclosure hardware.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:20px;\"\u003e\n        \u003ch3 style=\"margin:0 0 8px 0; color:#1A202C; font-size:17px; line-height:1.4; font-weight:700;\"\u003eProtect the Port with Natural Routing\u003c\/h3\u003e\n        \u003cp style=\"margin:0;\"\u003eThe right-angle design can reduce forced bending, but proper installation still matters. Leave a supported service loop, avoid pulling on either connector, and secure the cable so vehicle movement or equipment servicing does not transfer tension to the VE.Direct port.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Long-reach section --\u003e\n  \u003csection style=\"margin-bottom:30px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:24px 0 12px 0; line-height:1.35;\"\u003e5 Meters (16.4 Feet) for Long System Routing\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eConnect supported components across larger RV, marine, and off-grid electrical layouts.\u003c\/p\u003e\n    \u003cp style=\"margin:0 0 14px 0;\"\u003eThe 5-meter length gives installers meaningful routing flexibility without moving to Victron's maximum 10-meter VE.Direct cable. It can span an RV pass-through compartment, route from a boat helm to a nearby equipment bay, connect across a large electrical backboard, or reach between a battery monitor and a GX device mounted in a different cabinet.\u003c\/p\u003e\n    \u003cp style=\"margin:0;\"\u003eUse the full factory-terminated cable rather than cutting or splicing it. Measure the intended route—including service loops, bulkhead transitions, cable support, and connector access—before ordering. Do not pull the connectors through undersized holes or leave excess cable where it can be pinched or abraded.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:14px; margin-top:20px;\"\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:20px;\"\u003e\n        \u003ch3 style=\"margin:0 0 8px 0; color:#1A202C; font-size:17px; line-height:1.4; font-weight:700;\"\u003eConnect Distant Components\u003c\/h3\u003e\n        \u003cp style=\"margin:0;\"\u003eA 16-foot-class run is useful when a SmartShunt, BMV monitor, MPPT solar charger, Orion XS, or Smart IP43 charger is separated from the GX device by cabinetry, deck structure, an equipment board, or an adjacent storage compartment.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:12px; padding:20px;\"\u003e\n        \u003ch3 style=\"margin:0 0 8px 0; color:#1A202C; font-size:17px; line-height:1.4; font-weight:700;\"\u003eWithin Victron's Published Cable Limit\u003c\/h3\u003e\n        \u003cp style=\"margin:0;\"\u003eFive meters is an official Victron VE.Direct cable length and remains below the published 10-meter maximum. VE.Direct cables cannot be extended, so select one continuous cable long enough for the complete routed path.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Applications --\u003e\n  \u003csection style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(280px,1fr)); gap:22px; margin:30px 0; align-items:start;\"\u003e\n    \u003cdiv\u003e\n      \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:0 0 12px 0; line-height:1.35;\"\u003eVE.Direct Networking for Supported Victron Devices\u003c\/h2\u003e\n      \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eBring compatible component data into a central GX monitoring system.\u003c\/p\u003e\n      \u003cul style=\"list-style:none; padding:0; margin:0; display:grid; gap:8px;\"\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eConnect a supported SmartSolar or BlueSolar MPPT solar charger to a Cerbo GX, Ekrano GX, Color Control GX, or another compatible GX device.\u003c\/span\u003e\n\u003c\/li\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eRoute a SmartShunt or compatible BMV battery monitor to a distant GX hub for centralized battery data and supported VRM monitoring.\u003c\/span\u003e\n\u003c\/li\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eConnect supported Orion XS and Smart IP43 charger products whose manuals specify a direct VE.Direct-to-GX connection.\u003c\/span\u003e\n\u003c\/li\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eReduce rear-panel depth behind flush-mounted controls, shallow electrical boxes, compact boat helms, and RV cabinetry.\u003c\/span\u003e\n\u003c\/li\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eRoute data across larger electrical backboards and between adjacent equipment compartments without joining two VE.Direct cables.\u003c\/span\u003e\n\u003c\/li\u003e\n        \u003cli style=\"display:flex; gap:9px; align-items:flex-start; margin:0;\"\u003e\n\u003cspan style=\"color:#5EBB46; font-weight:800; line-height:1.6;\"\u003e✓\u003c\/span\u003e\u003cspan\u003eReplace a damaged or missing 5m right-angle cable with the exact genuine Victron part number ASS030531250.\u003c\/span\u003e\n\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003caside style=\"background:#F7FAFC; border:1px solid #E2E8F0; border-left:5px solid #ED1B4A; border-radius:12px; padding:22px;\"\u003e\n      \u003ch3 style=\"margin:0 0 10px 0; color:#1A202C; font-size:16px; line-height:1.4; font-weight:600; text-transform:none;\"\u003eConfirm the exact ports before ordering\u003c\/h3\u003e\n      \u003cp style=\"margin:0 0 12px 0;\"\u003eVE.Direct is a proprietary four-pin connection. It is not interchangeable with VE.Bus, VE.Can, BMS-Can, Ethernet, RJ45, RJ12, or USB cabling.\u003c\/p\u003e\n      \u003cp style=\"margin:0;\"\u003eSome Victron products have multiple communications ports or require a particular interface for GX integration. Match the connection method to the manuals for both devices rather than choosing a cable by product brand alone.\u003c\/p\u003e\n    \u003c\/aside\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Genuine quality --\u003e\n  \u003csection style=\"margin-bottom:32px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:24px 0 12px 0; line-height:1.35;\"\u003eGenuine Victron Quality for Reliable Data Routing\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eFactory-made connectors and the correct VE.Direct pinout—without improvised adapters.\u003c\/p\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(240px,1fr)); gap:12px;\"\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eProprietary 4-Pin VE.Direct Interface\u003c\/h3\u003eThe cable is made for Victron's four-contact VE.Direct connection, carrying the required conductors between compatible devices.\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eOne Angled, One Straight Connector\u003c\/h3\u003eThe right-angle end reduces depth where space is tight, while the straight end provides conventional access at the other device.\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eFactory-Molded Terminations\u003c\/h3\u003eGenuine connectors remove the pinout uncertainty and intermittent-fault risk associated with improvised splices or unrelated four-pin cords.\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eLong-Reach Mobile-System Routing\u003c\/h3\u003eThe 5-meter length is practical for RV, marine, vehicle, and off-grid electrical layouts when installed with proper support and strain relief.\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eGX Monitoring Integration\u003c\/h3\u003eUse with supported VE.Direct equipment to bring available operating data into a compatible GX device and, where configured, the VRM portal.\u003c\/div\u003e\n      \u003cdiv style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-radius:10px; padding:16px;\"\u003e\n\u003ch3 style=\"display:block; color:#1A202C; font-size:16px; line-height:1.4; font-weight:700; margin:0 0 5px 0;\"\u003eBluetooth Complements the Cable\u003c\/h3\u003eLocal Bluetooth setup remains useful, while the wired VE.Direct connection provides the supported path into a GX monitoring system.\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Installation --\u003e\n  \u003csection style=\"background:#F7FAFC; border:1px solid #E2E8F0; border-radius:14px; padding:22px; margin:0 0 32px 0;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:0 0 12px 0; line-height:1.35;\"\u003ePlug-and-Route Installation\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003ePlan the full 5-meter path before final panel mounting.\u003c\/p\u003e\n    \u003col style=\"margin:0; padding-left:22px; display:grid; gap:8px;\"\u003e\n      \u003cli\u003ePower down or isolate equipment as required by the applicable Victron installation manuals.\u003c\/li\u003e\n      \u003cli\u003eConfirm that both intended devices have the correct supported VE.Direct ports.\u003c\/li\u003e\n      \u003cli\u003eTest-fit the right-angle connector at the device with the shallowest rear clearance and verify the elbow direction.\u003c\/li\u003e\n      \u003cli\u003eRoute the cable away from sharp edges, heat sources, moving hardware, standing water, and high-current conductors where practical.\u003c\/li\u003e\n      \u003cli\u003eSupport the cable at intervals and provide a service loop so the device ports do not carry the cable's weight or installation tension.\u003c\/li\u003e\n      \u003cli\u003eInsert each connector fully without forcing it, then restore power and confirm that the connected device appears with expected data in the GX interface.\u003c\/li\u003e\n    \u003c\/ol\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Specifications --\u003e\n  \u003csection style=\"margin-bottom:34px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:24px 0 12px 0; line-height:1.35;\"\u003eTechnical Specifications\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eExact product identity, cable length, connector layout, and compatibility guidance.\u003c\/p\u003e\n    \u003cdiv style=\"border:1px solid #E2E8F0; border-radius:12px; overflow:hidden; background:#FFFFFF;\"\u003e\n      \u003cdiv style=\"background:#1A202C; color:#FFFFFF; padding:11px 14px; font-size:12px; font-weight:700; letter-spacing:0.12em; text-transform:uppercase;\"\u003eVictron VE.Direct Right Angle Cable 5m\u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eManufacturer\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eVictron Energy\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eProduct\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eVE.Direct cable, 5m, one side right-angle connection\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003ePart number \/ SKU\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eASS030531250\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eLength\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003e5 meters \/ approximately 16.4 feet\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eConnector 1\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eProprietary four-pin VE.Direct, 90-degree right-angle\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eConnector 2\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eProprietary four-pin VE.Direct, straight\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eCable family\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eASS030531xxx right-angle VE.Direct cable family\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003ePrimary purpose\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eDirect data connection between compatible products with VE.Direct ports\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eCompatible device examples\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eSupported BMV monitors, SmartShunts, SmartSolar \/ BlueSolar MPPTs, Orion XS units, Smart IP43 chargers, and compatible GX devices\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eGX device examples\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eCerbo GX, Ekrano GX, Color Control GX, and other GX devices with an available supported VE.Direct port\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eMaximum VE.Direct cable length\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003e10 meters total; VE.Direct cables cannot be extended\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eLonger-distance method\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eVE.Direct-to-USB interface with an appropriate active USB extension, following Victron guidance\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px; border-bottom:1px solid #E2E8F0; background:#FFFFFF;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eNot for\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eVE.Bus, VE.Can, BMS-Can, Ethernet, RJ45, RJ12, or direct USB connections\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"display:flex; flex-wrap:wrap; justify-content:space-between; gap:10px 20px; padding:10px 14px;  background:#F8FAFC;\"\u003e\n        \u003cspan style=\"flex:1 1 220px; font-weight:600; color:#1A202C;\"\u003eInstallation\u003c\/span\u003e\n        \u003cspan style=\"flex:2 1 260px; color:#2D3748;\"\u003eUse factory terminations; provide service loop and strain relief; protect from pinching, abrasion, heat, and moisture exposure beyond device requirements\u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Interface comparison --\u003e\n  \u003csection style=\"background:linear-gradient(135deg,#031725 0%,#06253D 100%); color:#FFFFFF; border-radius:14px; padding:26px; margin:32px 0; border:1px solid rgba(46,145,229,0.35);\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#FFFFFF; margin:0 0 12px 0; line-height:1.35;\"\u003eVE.Direct Is Not VE.Bus or VE.Can\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#7DC8FF; font-weight:600;\"\u003eChoose the cable by the physical ports and product manuals—not by the Victron name alone.\u003c\/p\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(220px,1fr)); gap:10px;\"\u003e\n      \u003cdiv style=\"background:rgba(255,255,255,0.07); border:1px solid rgba(125,200,255,0.35); border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#FFFFFF;\"\u003eVE.Direct\u003c\/strong\u003e\u003cspan style=\"color:#D9ECFF;\"\u003eSmall proprietary four-pin connection used by compatible monitors, chargers, controllers, and GX products.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv style=\"background:rgba(255,255,255,0.07); border:1px solid rgba(125,200,255,0.35); border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#FFFFFF;\"\u003eVE.Bus \/ VE.Can\u003c\/strong\u003e\u003cspan style=\"color:#D9ECFF;\"\u003eRJ45-based systems that require the correct cable, port, network profile, and termination instructions.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv style=\"background:rgba(255,255,255,0.07); border:1px solid rgba(125,200,255,0.35); border-radius:10px; padding:14px;\"\u003e\n\u003cstrong style=\"display:block; color:#FFFFFF;\"\u003eVE.Direct to USB\u003c\/strong\u003e\u003cspan style=\"color:#D9ECFF;\"\u003eA separate interface used when the destination is USB or when Victron's longer-distance USB method is required.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- FAQ --\u003e\n  \u003csection style=\"margin-top:40px;\"\u003e\n    \u003cdiv style=\"text-align:center; margin-bottom:24px;\"\u003e\u003cspan style=\"color:#2E91E5; text-transform:uppercase; letter-spacing:0.16em; font-size:12px; font-weight:700;\"\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/div\u003e\n    \u003ch2 style=\"color:#1A202C; font-size:26px; line-height:1.2; margin:0 0 8px 0; font-weight:700; text-align:center;\"\u003eVictron VE.Direct Right Angle Cable 5m FAQs\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 26px 0; color:#4A5568; text-align:center;\"\u003eCompatibility, connector orientation, clearance, long routing, and GX integration guidance for ASS030531250.\u003c\/p\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:1fr; gap:12px;\"\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #2E91E5; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eAre both ends of the Victron ASS030531250 cable right-angled?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eNo. ASS030531250 is the 5-meter VE.Direct cable with one 90-degree right-angle connector and one standard straight connector. Place the angled end at the compatible device that needs the least rear clearance, provided the connector direction does not obstruct nearby ports or the enclosure.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #5EBB46; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eWhy would I choose a right-angle VE.Direct cable instead of a straight cable?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eVictron designed the ASS030531xxx right-angle cable family to minimize the depth required behind mounting panels. The 90-degree connector turns the cable alongside the equipment instead of projecting straight outward, which can simplify flush-mounted RV control panels, marine dashboards, and shallow electrical cabinets while reducing forced bends at the port.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #ED1B4A; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eHow long is the Victron VE.Direct Right Angle Cable 5m in feet?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eThe cable is 5 meters long, which is approximately 16.4 feet. This length is useful when a compatible VE.Direct device and GX monitoring hub are mounted in separate cabinets, across an RV storage bay, or between a boat helm and a nearby electrical compartment.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #2E91E5; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eWhat is the Victron ASS030531250 VE.Direct cable used to connect?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eIt creates a direct data connection between compatible products with VE.Direct ports. Common examples include supported SmartSolar or BlueSolar MPPT solar chargers, BMV battery monitors, SmartShunts, Orion XS units, and Smart IP43 chargers connected to a Cerbo GX, Ekrano GX, Color Control GX, or another compatible GX device with an available VE.Direct port.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #5EBB46; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eWill a 5-meter VE.Direct cable cause signal loss?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eFive meters is an official Victron factory cable length and is within Victron's published 10-meter maximum for VE.Direct cabling. Reliable operation still depends on using the correct ports, keeping the factory connectors intact, providing strain relief, and routing the cable away from damage or severe electrical interference. Avoid splices, couplers, and improvised four-pin leads.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #ED1B4A; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eWhich Victron products are compatible with this right-angle VE.Direct cable?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eCompatibility depends on both devices having supported VE.Direct ports and on the connection method specified in their manuals. Typical examples include many BMV battery monitors, SmartShunts, SmartSolar and BlueSolar MPPT solar chargers, Orion XS products, Smart IP43 chargers, and compatible GX devices. Always verify the exact model and available port before ordering.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #2E91E5; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eCan I use this cable to connect a MultiPlus or Quattro to a Cerbo GX?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eNo. MultiPlus and Quattro inverter\/chargers normally communicate through VE.Bus, which uses a straight-through RJ45 UTP cable. This product uses the smaller proprietary four-pin VE.Direct interface and will not fit VE.Bus, VE.Can, BMS-Can, Ethernet, RJ12, or USB ports.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #5EBB46; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eCan this 5m VE.Direct cable be extended or joined to another cable?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eNo. Victron specifies a maximum VE.Direct cable length of 10 meters and states that VE.Direct cables cannot be extended. Use one continuous factory-made cable in the required length. For routes longer than 10 meters, follow Victron guidance for a VE.Direct-to-USB interface with an appropriate active USB extension.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #ED1B4A; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eWhich end of the cable should use the 90-degree connector?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003ePlace the right-angle end at the compatible VE.Direct device that needs reduced rear depth, provided the connector orientation does not block adjacent ports or interfere with the enclosure. Test-fit the cable before final mounting and leave enough service loop so neither connector is pulled, twisted, or sharply bent.\u003c\/p\u003e\n      \u003c\/details\u003e\n      \u003cdetails style=\"background:#FFFFFF; border:1px solid #E2E8F0; border-left:5px solid #2E91E5; border-radius:10px; padding:18px;\"\u003e\n        \u003csummary style=\"cursor:pointer; color:#1A202C; font-weight:700; font-size:16px; line-height:1.45;\"\u003eDo I need a VE.Direct cable if my SmartSolar or SmartShunt has Bluetooth?\u003c\/summary\u003e\n        \u003cp style=\"margin:14px 0 0 0; color:#2D3748;\"\u003eBluetooth is useful for local setup and monitoring through VictronConnect, but it does not replace a direct VE.Direct connection when the device needs to report to a Cerbo GX or another GX system. Use this cable for supported centralized monitoring and VRM integration through the GX device.\u003c\/p\u003e\n      \u003c\/details\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- Final note --\u003e\n  \u003csection style=\"margin-top:32px;\"\u003e\n    \u003ch2 style=\"font-size:18px; font-weight:600; letter-spacing:0.05em; text-transform:uppercase; color:#1A202C; margin:24px 0 12px 0; line-height:1.35;\"\u003eCompatibility \u0026amp; Installation Note\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px 0; color:#2E91E5; font-weight:600;\"\u003eConfirm the exact ports, connector direction, and device manuals before connecting.\u003c\/p\u003e\n    \u003cp style=\"margin:0;\"\u003eNot every Victron product uses VE.Direct, and some products with multiple communication interfaces require a specific port or connection method for GX integration. Measure the complete routed path, test-fit the angled end before final panel mounting, keep the factory terminations intact, and install the cable where it will not be pinched, pulled, abraded, exposed to damaging heat, or confused with RJ45 VE.Bus or VE.Can wiring.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":42608609067054,"sku":"ASS030531250","price":22.1,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/0484\/2798\/files\/epoch_victron_ve_direct_right_angle_cable_professional_reflection_a01ee76a-76fa-4ee5-94eb-96821ed67c36.png?v=1785587224","url":"https:\/\/epochbatteries.myshopify.com\/products\/victron-ve-direct-right-angle-cable-5m-ass030531250","provider":"Epoch Batteries","version":"1.0","type":"link"}